IKA LR-2.ST Starvisc 200 Laboratory Reactor, Measuring Stirrer, 0020020603
€17,432.50
% Manufacturer's RRP: €18,350.00 5% below manufacturer's RRP
- STARVISC 200-2.5 control measuring stirrer with calibrated torque and viscosity measurement during the reaction
- Working volume 500 to 2,000 ml, from 800 ml with dispersing tool
- Working temperature -50 to 230 °C, vacuum operation down to 25 mbar
- Viscosity up to 100,000 mPas, torque up to 200 Ncm at the stirring shaft
- Supplied as a stand system with base component, reactor head and measuring stirrer, without reactor vessel
Product information "IKA LR-2.ST Starvisc 200 Laboratory Reactor, Measuring Stirrer, 0020020603"
Anyone developing a chemical reaction on a laboratory scale and later wanting to transfer it to a larger scale needs more than a stirrer display that only reports a trend. The IKA LR-2.ST Starvisc 200 laboratory reactor measures torque and viscosity directly at the STARVISC 200-2.5 control measuring stirrer while the reaction is running, not afterwards on a separate viscometer. This distinguishes it from the four other versions of the LR-2.ST series, which work with EUROSTAR stirrers and a general torque trend display but provide no calibrated measurement. For high-viscosity media up to 100,000 mPas and working volumes of 500 to 2,000 ml, the system therefore delivers reproducible measured values for process development instead of just a rough estimate.
The complete stand system is supplied: the LR.SI base component, the HEAD,REACTOR,LR2.10 reactor lid and the STARVISC 200-2.5 control measuring stirrer. The reactor vessel itself is not included in the scope of delivery. The glass vessel is ordered separately to match the required working volume. This applies equally to all five variants of the LR-2.ST series and should be planned for with the first order of a system.
True torque and viscosity measurement during the reaction
The STARVISC 200-2.5 control measures torque and the viscosity derived from it in a calibrated way at the stirring shaft, with a maximum value of 200 Ncm. This is exactly what makes the difference from the general torque trend display of the other LR-2.ST variants: there the display shows whether the torque is rising or falling, here there is a reliable measured value that can be documented and taken into an evaluation. For product development in which viscosity profiles during a reaction (for example in polymerisations or when resins cure) decide the process quality, this is the real reason to buy this model within the series. The minimum speed of 6 rpm additionally allows very slow stirring when a reaction tolerates only little shear energy.
Temperature range, working volume and vacuum operation
The working volume is between 500 and 2,000 ml. With a dispersing tool, at least 800 ml should be in the vessel so that the shearing action does not run into empty space. The working temperature ranges from -50 to 230 °C, and the telescopic stand has a stroke of 390 mm for different vessel sizes and set-ups. Vacuum operation down to 25 mbar is possible, for example for degassing media or for reactions that are to take place at reduced pressure. The product-contacting parts of the system itself are made of borosilicate glass, FFPM, PTFE and steel 1.4571. The reactor lid has three NS 29/32 openings and two NS 14/23 openings for sensors, additions or a reflux condenser.
Reproducibility and documentation of the measured values
For process development, besides the measured value itself, it also matters that a stirring experiment can later be repeated identically. Because the STARVISC 200-2.5 control records torque and viscosity continuously, a batch can be evaluated over time and compared with later batches, instead of merely noting a subjective assessment of the stirrer display. When transferring laboratory results to a larger scale, this traceability is often more important than a single measurement, because deviations between two batches only show up in comparison. For laboratories with documented equipment qualification, factory calibration certificates and IQ/OQ documents for the system are also available, see the section on the procurement service. Especially when comparing different recipes or batches, the system thus provides an objective basis on which decisions in the laboratory can be founded, instead of relying on the impression of a single person at the stirrer.
Typical applications
- Optimisation and reproduction of chemical reaction, mixing and homogenising processes on a laboratory scale
- Product development requiring documented torque and viscosity measurement during the reaction, for example with polymerisations, resins or adhesives
- Processing of high-viscosity media up to 100,000 mPas
- Reactions under vacuum or reduced pressure, for example for degassing
- Scale-up preparatory work before moving to a larger production scale
Selection guide within the LR-2.ST family
The LR-2.ST series is available in five versions with the same stand system and reactor lid, but different stirrers. The stirrer determines torque, maximum viscosity and whether a calibrated measurement is possible:
| Version | Stirrer, max. torque, max. viscosity, measuring function |
| Starvisc 200 (this device) | STARVISC 200-2.5 control, 200 Ncm, 100,000 mPas, calibrated torque and viscosity measurement |
| LR-2.ST the High-Performer | EUROSTAR 660 high torque control, 660 Ncm, 150,000 mPas, torque trend display only |
| LR-2.ST the Allrounder | EUROSTAR 200 control, 200 Ncm, 100,000 mPas, torque trend display only |
| LR-2.ST the Versatile | EUROSTAR 100 control with clockwise/anticlockwise rotation, 100 Ncm, 70,000 mPas, torque trend display only |
| LR-2.ST the Compact Power | EUROSTAR 60 control, 60 Ncm, 50,000 mPas, torque trend display only |
Anyone who actually has to measure and document viscosity during the reaction cannot get around the Starvisc 200 version. If a pure trend display is sufficient and higher torque for very viscous media is wanted instead, the LR-2.ST the High-Performer is the more suitable choice. For applications with lower viscosity requirements and a smaller budget, the LR-2.ST the Allrounder, the LR-2.ST the Versatile and the LR-2.ST the Compact Power are available. The STARVISC 200-2.5 control measuring stirrer is also available separately as a replacement or retrofit part if required.
Technical details
| Working volume | 500 to 2,000 ml |
| Working volume with dispersing tool | at least 800 ml |
| Working temperature | -50 to 230 °C |
| Achievable vacuum | 25 mbar |
| Max. viscosity | 100,000 mPas |
| Min. speed | 6 rpm |
| Telescopic stand stroke | 390 mm |
| Product-contacting material | Borosilicate glass, FFPM, PTFE, steel 1.4571 |
| Reactor vessel openings | 3 x NS 29/32, 2 x NS 14/23 |
| Max. torque at the stirring shaft | 200 Ncm |
| Permissible ambient temperature range | 5 to 40 °C |
| Permissible relative humidity | 80 % |
| Dimensions (W x H x D) | 670 x 1240 x 580 mm |
| Weight | 25 kg |
Scope of delivery
- 1 x LR-2.ST stand system
- 1 x LR.SI base and stand component
- 1 x HEAD,REACTOR,LR2.10 reactor lid
- 1 x STARVISC 200-2.5 control torque measuring stirrer
The reactor vessel is not part of the scope of delivery. The glass vessel is ordered separately to match the required working volume, as are accessories such as stirring elements for other applications, temperature probes, a vacuum pump or a circulating thermostat, if these are not yet available.
Use and maintenance
The system weighs 25 kg and belongs on a stable, level work surface with sufficient load capacity. Before each vacuum operation, a brief visual check of the standard ground joint connections at the lid is worthwhile, as a leak otherwise costs vacuum performance. The permissible ambient temperature range is 5 to 40 °C, the permissible relative humidity 80 %. After stirring high-viscosity or sticky media, the measuring stirrer can be detached from the lid for cleaning without dismantling the entire stand system. When changing between media of different viscosity, it makes sense to check the measuring stirrer for residues before the next batch, because dried-on residues can falsify the torque measurement. At the end of its service life, the system belongs, as electrical equipment, in the separate collection of waste electrical and electronic equipment, not in household waste.
Individual requirements and procurement service
For the LR-2.ST Starvisc 200, IKA offers an extensive accessory range: reactor vessels in different volumes, further stirring elements such as anchor stirrers or baffles, dispersing tools of the T 25 series, pH and temperature probes, vacuum pumps and controllers, and circulating thermostats for active temperature control. Factory calibration certificates and IQ/OQ documentation are also available if required. Through our procurement service, LT Laborhandel supports you in putting together the right reactor vessel and further components for your LR-2.ST system. In making the selection we take into account the planned working volume, type of medium and process temperature, so that vessel and drive match each other.
Frequently asked questions
Is a reactor vessel included in the scope of delivery?
No. The Starvisc 200 is supplied as a stand system with base component, reactor lid and measuring stirrer. The glass vessel is ordered separately to match the working volume.
How does the Starvisc 200 differ from the other LR-2.ST models?
In the stirrer. Only the Starvisc 200 measures torque and viscosity in a calibrated way during the reaction, while the other four variants show only a general torque trend.
Up to what viscosity can it stir?
Up to 100,000 mPas, at a maximum torque of 200 Ncm at the stirring shaft.
Can the system be operated under vacuum?
Yes, down to 25 mbar, for example for degassing media.
What working volume is intended?
500 to 2,000 ml. With a dispersing tool, at least 800 ml should be in the vessel.
How heavy is the system and what should I bear in mind when setting it up?
The stand system weighs 25 kg. It belongs on a stable, level work surface that can safely carry this weight.