Skip to main content Skip to search Skip to main navigation

IKA RCT basic Synthesis Solution 250 Magnetic Stirrer Complete Pack, Aluminium Base Plate, 0010016490

Product information "IKA RCT basic Synthesis Solution 250 Magnetic Stirrer Complete Pack, Aluminium Base Plate, 0010016490"

A glass flask is not very forgiving if, during reflux distillation, a sensor cable rubs against the clamp or if an oil bath spills onto the hotplate should the flask break. The IKA RCT basic Synthesis Solution 250 (ID No. 0010016490) addresses both issues: a wireless temperature sensor measures directly within the reaction medium, a second, wired sensor simultaneously monitors the synthesis block, and the flask is housed in an aluminium block rather than in an open oil bath. IKA supplies the complete set for round-bottom flasks up to 250 millilitres: the RCT basic magnetic stirrer with heating, flask holder, PT wireless and PT1000 sensors, USB dongle, as well as a stand and clamps for securing the flask.

Wireless temperature and pH measurement in the reaction medium

The centrepiece of the set is the PT wireless sensor, which transmits measurement values wirelessly to the RCT basic. A pH electrode can also be connected via the PT wireless’s BNC socket; the RCT basic’s display then shows the pH value directly, without the need for a separate measuring device. As there is no longer a sensor cable leading to the flask, the setup on the stand remains more flexible, and there is no risk of cables being damaged or scorched by contact with the heating plate. The supplied USB WD dongle also connects the RCT basic wirelessly to the IKA Lab Assistant app for visualising the measurement data.

Dual temperature monitoring for greater safety

In addition to the PT wireless, the set includes the wired PT 1000.60 sensor. Both sensors measure simultaneously, but at different locations: the PT 1000.60 monitors and limits the temperature at the synthesis block or heat transfer medium, whilst the PT wireless measures the temperature directly within the reaction medium. The RCT basic displays both values side by side on the screen. This separate measurement is particularly important in the event of glass breakage, as a sudden discrepancy between the block temperature and the medium temperature becomes immediately apparent and does not have to be detected via a single measurement point.

Synthesis block instead of an oil bath

The flask holder supplied (IKA designation H 135.25, for 250 ml round-bottom flasks, without handle) is a synthesis block made of solid anodised aluminium and is temperature-resistant up to 300 degrees Celsius. Compared to an oil or sand bath, this significantly reduces the potential for hazards and simplifies handling and cleaning, as there is no risk of an oil bath leaking or sand becoming stuck. A universal clamp (R 350) additionally secures the flask to the stand. The RCT basic has a second stand mount, which can be used to attach an additional stand rod for a reflux condenser if required.

RCT basic as a basic unit: stirring and heating with 800 watts

The basic unit covers a speed range of 50 to 1,500 revolutions per minute, adjusted via a rotary-push control with an accuracy of 10 revolutions per minute. Stirring rods with lengths of 20 to 80 millimetres can be used; according to the data sheet, the stirring capacity is up to 20 litres of water, and the maximum load is 25 kilograms. The heater has an output of 800 watts and reaches temperatures ranging from room temperature to 310 degrees Celsius; one litre of water heats up by 9 Kelvin per minute in heating stage H1500. The safety limit can be set independently of the setpoint between 50 and 360 degrees Celsius – a control logic that IKA has been using for decades in heated equipment. The die-cast aluminium housing is rated to IP 54, which protects against splashing water and corrosive laboratory air.

Safety concept for unattended operation

Beneath the heating plate are two further, separate temperature sensors: one controls the setpoint temperature, whilst the second monitors an independently adjustable safety limit in accordance with EN IEC 61010-2-010; this setting is adjusted mechanically directly on the unit and is independent of the process setpoint. If the medium temperature drops suddenly – for example, due to glass breakage or the medium evaporating – the RCT basic detects this and can switch off the heating. If the temperature fails to rise despite the power supply – for example, because a sensor is not immersed in the medium – the device also deactivates the heating automatically. A visual warning is also displayed as soon as the mounting surface exceeds 50 degrees Celsius, even if the unit is already switched off.

Differences compared to the larger sets in the series

The Synthesis Solution 250 shares the base unit with the 500 and 1,000 millilitre sets; the flask holder in all three sets is tailored to the respective flask volume. If you mainly carry out small experiments up to 250 millilitres, this set will suffice. If your experiments regularly reach 500 or 1,000 millilitres, the corresponding larger sets are the more obvious choice. It has not been verified at this stage whether the 500 and 1000 millilitre sets include the same range of wireless sensors as the 250-ml set; the shop descriptions for these sets to date only mention the wired PT1000 probe.

Typical applications

As a synthesis kit with wireless sensor technology, the RCT basic Synthesis Solution 250 is suitable for, amongst other things:

  • Organic syntheses on a 250-ml scale with simultaneous monitoring of block and medium temperatures
  • Refluxing, where an additional stand rod is required for the condenser
  • pH monitoring directly in the reaction mixture, without a separate pH meter at the workstation
  • Laboratory workstations that wish to avoid open oil baths for safety or cleaning reasons

Technical details

Number of stirring points1
Max. stirring volume (H₂O)20 l
Maximum load25 kg
Motor power output9 W, brushless DC motor
Speed range50 to 1500 rpm
Speed adjustment accuracy10 rpm
Stirrer rod length20 to 80 mm
Heating power800 W
Heating temperature rangeRoom temperature to 310 °C
Heating rate (1 l H₂O, heating setting H1500)9 K/min
Adjustable safety circuit50 to 360 °C
Control accuracy with PT1000 (500 ml H₂O, 40 mm rod, 600 rpm, 50 °C)±0.5 K
Base plate materialAluminium alloy, Ø 135 mm
Protection class according to DIN EN 60529IP 54
InterfacesRS232, USB-C, USB WD dongle (wireless)
Dimensions of base unit (W x H x D)160 x 100 x 200 mm
Net weight of base unit2.3 kg
Power supply220 to 230 V, 50/60 Hz
Power consumption820 W
Piston carrier volume250 ml, without handle
Flask holder materialAnodised aluminium, temperature-resistant up to 300 °C
Wired temperature probePT 1000.60, stainless steel
Wireless temperature probePT wireless, with BNC connector for optional pH electrode

Contents

  • 1 x IKA RCT basic magnetic stirrer with heating
  • 1 x PT wireless, wireless temperature probe
  • 1 x H 16 V support rod
  • 1 x support rod H 38
  • 2 x H 44 cross-sleeve
  • 1 x H 80 bracket for the temperature probe
  • 1 x R 350 universal clamp
  • 1 x PT 1000.60 temperature probe, stainless steel
  • 1 x USB WD, USB dongle for the RCT basic
  • 1 x flask holder H 135.25 for 250 ml round-bottom flasks, without handle
  • 5 x IKAFLON 25 ellipse, magnetic stirring bars
  • 1 x IKAFLON 30 magnetic stir bar
  • 1 x IKAFLON 40 magnetic stirring bar
  • 1 x screwdriver for assembly

Customised requirements & procurement service

Those who regularly carry out larger batches will find the IKA RCT basic Synthesis Solution 500 (MPN 0010016483) or the Synthesis Solution 1000 (MPN 0010016478) to be the ideal set for 500 or 1000 millilitres respectively. IKA offers a range of accessories for the RCT basic, including a protective cover H 105 and a flask holder H 135.31 for 500-ml round-bottom flasks with handles. For further accessories, spare parts or bespoke calibration, please contact the procurement service at LT Laborhandel, available at lt-laborhandel.de/service.

Skip product gallery

Matching accessories

Discount
IKA IKAFLON round Magnetrührstäbchen, PTFE-beschichtet, für RCT/RET basic
IKA IKAFLON round Magnetic Stirring Bar, PTFE-Coated, for RCT/RET basic

IKA IKAFLON round magnetic stirring bars are PTFE-coated stirring cores with a round cross-section for use on IKA magnetic stirrers. The PTFE coating is chemically resistant to most common laboratory solvents and acids and cleans without residue, which makes the bars practical when switching between different batches.The series is available in five lengths from 15 to 50 mm, each in a pack of 5, so a suitably sized stirring core can be chosen for different vessel sizes and fill volumes, avoiding a bar that is too small spinning erratically in a large vessel or one that is too large getting stuck at the vessel base.CompatibilityThe IKAFLON 15 round is official accessory for the IKA RCT basic anodised magnetic stirrer with heating (MPN 0020133785), RET basic magnetic stirrer with heating (MPN 0025008265), RET basic anodised magnetic stirrer with heating (MPN 0020133787) and RH lite magnetic stirrer with heating (MPN 0020007108). The 25, 30, 40 and 50 mm lengths suit the RCT basic anodised, RET basic and RET basic anodised. For the RH lite we recommend the 15 mm length.Technical detailsIKAFLON 15 round15 x 6 mm, PTFE-coated, 5 pcs.IKAFLON 25 round25 x 8 mm, PTFE-coated, 5 pcs.IKAFLON 30 round30 x 8 mm, PTFE-coated, 5 pcs.IKAFLON 40 round40 x 8 mm, PTFE-coated, 5 pcs.IKAFLON 50 round50 x 8 mm, PTFE-coated, 5 pcs.Contents of the package1 x pack of 5 IKAFLON round magnetic stirring bars in the selected length.Individual requirements & procurement serviceFor external temperature control at the stirring vessel we also carry the matching PT 1000.60 temperature sensor. Our procurement service advises on the right stirring bar size for your vessel volume.

Sale price: €11.78 Manufacturer's RRP: €12.40 5% below manufacturer's RRP
Discount
IKA ETS-D5 electronic contact thermometer with touchscreen, –20 °C to +400 °C, 0025008371
IKA ETS-D5 electronic contact thermometer with touchscreen, –20 °C to +400 °C, 0025008371
Herstellernummer: 0025008371

The new IKA ETS-D5 electronic contact thermometer (MPN 0025008371) completely redefines precision, safety and ease of use in laboratory thermal analysis. Developed as a high-performance mechatronic control unit for demanding laboratory processes, this instrument takes over active, direct temperature control of the medium once connected. It controls the heating power of a coupled magnetic stirrer by intelligently switching the heating plate on and off, whilst the stirrer itself acts as a redundant monitoring unit for the preset safety limits. The ETS-D5 thus transforms any compatible workstation into a future-proof, high-precision control centre for reproducible experimental series. Integrated safety architecture for risk-free processes From a process engineering perspective, the ETS-D5 offers a comprehensive range of sophisticated protective functions that contribute significantly to laboratory safety and risk minimisation. The system features an adjustable sensor timeout, which is triggered immediately if the probe is inadvertently outside the liquid medium. Precise temperature drop detection reacts dynamically to unexpected thermal gradients, whilst setpoint monitoring (Delta T) immediately stops temperature control if the target value is exceeded by a critical margin. To prevent operator errors in multi-user operation, the maximum settable temperature can be strictly limited via a setpoint limit. In the event of a transient fault, the heating circuit remains permanently switched off to protect personnel and the sample matrix. Optimised PID control and application-specific modes The instrument’s control technology ensures absolutely stable temperature control without thermal overshoot. Coupled with a high-precision, interchangeable PT1000 temperature sensor of tolerance class A, the system covers a wide operating range from –20 °C to +400 °C. Three application-specific temperature control modes ensure maximum flexibility in day-to-day laboratory work: ‘Fast’ for ultra-fast heating cycles, ‘Precise’ for working at the minimum tolerance limit, and a specialised synthesis block mode that is perfectly tailored to the thermodynamic requirements of chemical syntheses. For highly sensitive organic or biological sample structures, the heating rate can also be precisely reduced in percentage increments. Ergonomic touch-screen control concept and documentation The instrument’s exterior breaks away from complicated analogue designs and features a user-friendly, clear touchscreen display for intuitive parameter configuration during continuous operation. The almost completely enclosed system reliably protects the internal electronic components from aggressive vapours and liquids in the harsh everyday laboratory environment. A future-proof, integrated USB-C interface also enables the rapid, error-free export of all transient measurement data to a PC, thereby ensuring seamless documentation, validation and traceability of your processes in accordance with modern GLP standards. Technical details Measurement system & control characteristics Sensor type: PT1000 (DIN IEC 751 Class A), easily replaceable Temperature measurement range: –20 °C to +400 °C Measurement and setpoint resolution: 0.1 K Temperature measurement accuracy: ±0.2 K + tolerance of the PT1000 sensor Control accuracy in the medium: ±0.5 K (validated with 500 ml of water in a 600-ml beaker) Temperature control modes: Fast, Precise (highest accuracy), Synthesis block-optimised Heating rate: Individually adjustable in percentage steps for sensitive samples Control algorithm: Optimised PID control to prevent overshoot Safety & monitoring functions Sensor timeout: Detects the absence of the sensor in the medium (time-adjustable) Temperature drop detection: Automatic response to unexpected temperature drops Setpoint monitoring (Delta T): Shuts off the heating function if the Delta T limit is exceeded Setpoint Limitation: Software-based limitation of the maximum settable temperature Safe-Temp & Emergency Protection: Immediate safety shutdown of the heating circuit in the event of a fault; the stirrer remains deactivated Operation, Interfaces & Geometry Display technology: User-friendly, flat touchscreen for intuitive operation Digital interface: USB-C for direct data transfer and software connection to a PC Connector to the main unit: DIN 45322 (MAS6 standard) Dimensions (width x height x depth): 52 x 36 x 385 mm Minimum probe insertion depth: 20 mm Net weight: 0.156 kg (156 grams) Environmental data & electrical specifications Protection class according to DIN EN 60529: IP 54 (dust- and splash-proof) Operating voltage / DC voltage: 8 to 16 V= Current consumption: 100 mA Permissible ambient temperature: +5 to +40 degrees Celsius Permissible relative humidity: Up to 80 per cent Contents of the package 1 x IKA ETS-D5 electronic contact thermometer (MPN: 0025008371) 1 x PT1000 temperature probe (standard version) 1 x USB-C connection cable 1 x Detailed operating instructions / safety guide Individual Requirements & Accessories To ensure optimal utilisation of the intelligent ETS-D5 control centre, we offer a complementary range of original system peripherals: Specialised probes for corrosive media: Optional interchangeable sensors made from robust special-purpose glass (H66.51) or featuring a highly chemically resistant protective coating (H66.53) for safe operation in acids and alkalis. Mechanical mounts: Precisely fitting extension cables for flexible spatial extension of the measuring station, as well as sturdy IKA support rods and cross-couplings for vibration-free stand locking above the sample point. Compatible stirring systems: Ideal as a metrological upgrade for IKA magnetic stirrers without integrated primary temperature control, to establish a redundant, independent medium safety circuit. Use our technical B2B procurement service to configure your measuring stations.

Sale price: €295.80 Manufacturer's RRP: €348.00 15% below manufacturer's RRP
Discount
IKA ETS-D7 Wireless Sensor, smart wireless temperature sensor and pH meter, 0025008370
IKA ETS-D7 Wireless Sensor, smart wireless temperature sensor and pH meter, 0025008370
Herstellernummer: 0025008370

The IKA ETS-D7 Wireless Sensor (MPN 0025008370) is a highly innovative, mechatronic, high-end wireless system solution for the simultaneous thermal and electrochemical analysis of samples in the modern laboratory. Far more than a conventional measuring transducer, this wireless instrument functions as an intelligent sensor and control centre. It transmits transient temperature data via digital radio transmission (WPAN) over a distance of up to 15 metres to compatible IKA drives, such as the magnetic stirrers of the RET basic and RCT basic series or the Eurostar control stirrers. This technological decoupling completely eliminates disruptive signal cables in the fume cupboard or glovebox and takes occupational safety and mechanical flexibility to a new level. All-in-one dual measurement technology with integrated BNC interface An outstanding technical feature of the ETS-D7 is its versatile configuration as a self-contained, stand-alone measuring device. The compact module features an integrated BNC socket, to which an analogue pH electrode can be connected directly. This transforms the temperature sensor into a fully-fledged, portable pH meter without the need for costly additional investment. The integrated, high-contrast TFT touchscreen displays both the temperature readings and the transient pH value with a fine metrological resolution of two decimal places (0.01). This guarantees absolutely error-free and precise readability of all process parameters directly at the physical measurement site. Smart sensor technology and highly efficient energy management The wireless sensor’s electronic system architecture stands out thanks to its forward-looking, software-controlled energy management. Using integrated infrared and ambient light sensors, the device automatically detects whether laboratory staff are in the immediate vicinity to read the measurements. The display only activates when actually needed (Auto-Wake) and automatically switches to a deep standby mode when idle, thereby achieving a remarkable battery life of up to 100 hours. For test series requiring continuous visual monitoring, continuous display operation can be flexibly enabled. Bidirectional connectivity for seamless Industry 4.0 validation Thanks to a sophisticated bidirectional communication matrix, the ETS-D7 enables full synchronisation of setpoint and actual values in a networked laboratory. Depending on the connected main unit, adjustments to temperature and stirring parameters can be made directly via the sensor’s touch interface. Furthermore, the sensor can be integrated as a second, redundant temperature sensor into critical safety control loops to reliably prevent exothermic incidents. Full compatibility with the labworldsoft (LWS) laboratory software ensures seamless digital recording, centralised control and audit-compliant documentation of all transient measurement curves in accordance with modern quality management standards. Technical details Measurement system & sensors Sensor type: PT1000 (DIN IEC 751 Class A), flexibly interchangeable Interchangeable probe: standard component H62.51 Temperature measurement range: –20 °C to +400 °C (in combination with H62 sensor) Temperature measurement resolution: 0.01 K Temperature measurement accuracy: ±0.05 K + tolerance of the PT1000 sensor Minimum immersion depth: 20 mm pH measurement function: Yes, via integrated BNC socket (female) pH measurement range: 0 to 14 pH pH resolution / accuracy: 0.01 pH / ±0.1 pH Operation, interfaces & wireless technology Display technology: Brilliant TFT touchscreen with full touch functionality Proximity sensors: Integrated infrared and brightness detection for intelligent auto-wake operation Signalling: Visual status LED and integrated audible warning function Wireless interface: WPAN (digital radio transmission) Communication range: Up to 15 metres (depending on the building structure) Wired interface: USB-C (for direct PC connection and alternative data transfer) Power management & battery Power supply: Built-in, rechargeable battery Battery capacity / DC voltage: 700 mAh / 5 V= Maximum charging current: 500 mA Operating time (display permanently ON): Up to 50 hours Operating time (display in auto-wake mode): Up to 100 hours Charging rate: 50% capacity in 60 minutes; 75% capacity in 90 minutes Design & environmental specifications Dimensions (width x depth x height): 52 x 385 x 40 mm Net weight: 0.125 kg (lightweight at 125 grams for flexible handling) Protection class according to DIN EN 60529: IP 54 (complete protection against dust and splashing water) Permissible ambient temperature: +5 to +40 degrees Celsius Permissible relative humidity: Up to 80 per cent Contents of the pack 1 x IKA ETS-D7 Wireless Sensor main unit (MPN: 0025008370) 1 x Replaceable temperature probe H62.51 1 x Integrated lithium-ion battery (700 mAh) 1 x Quick Start Guide / Safety Guide Note: A pH electrode and a USB-C charging adapter must be ordered separately as accessories. Customised requirements & accessories To make the most of the IKA ETS-D7’s multifunctional capabilities, we stock a wide range of compatible system peripherals: pH electrodes: High-quality laboratory measuring chains with standardised BNC connectors, perfectly suited to aqueous media, viscous samples or aggressive organic matrices. Wireless receiver (USB WD): For wireless integration and retrofitting of older RCT basic magnetic stirrers without a built-in WPAN module. Software & Mounting: labworldsoft (LWS) laboratory software for transient measurement data acquisition, as well as IKA support rods and cross-sockets for stable, vibration-free mounting of the sensor directly above the sample vessel. Please use our technical procurement service to configure your networked measurement station.

Sale price: €423.30 Manufacturer's RRP: €498.00 15% below manufacturer's RRP
IKA Pt.Wireless wireless sensor for temperature and pH measurement, 0025008369
IKA Pt.Wireless wireless sensor for temperature and pH measurement, 0025008369
Herstellernummer: 0025008369

The IKA Pt.Wireless wireless sensor (MPN 0025008369) represents a technologically pioneering, highly optimised mechatronic system solution for seamless digital temperature and electrochemical sample analysis in the laboratory. Designed as an intelligent, fully wireless sensor, this instrument eliminates the need for cumbersome cable routing in fume cupboards, gloveboxes or on crowded laboratory workstations. Via digital radio transmission (WPAN), the system transmits transient measurement data in real time over a range of up to 15 metres to compatible IKA system components – such as the latest generations of the RCT basic and RET basic magnetic stirrer series, Eurostar control stirrers, and directly to the labworldsoft (LWS) laboratory equipment software. Full app integration and display-free efficiency Unlike traditional measuring instruments, the Pt.Wireless does away with physically bulky display elements on the sensor itself and shifts all visual control to the innovative IKA app. Once paired – a straightforward process – the smartphone or tablet acts as a high-resolution dashboard for the real-time display of all parameters. Calibration of the precise temperature and pH calibration curves is also carried out error-free directly via the app’s user interface. For electrochemical analysis, the slim module features an integrated BNC interface to which an analogue pH electrode can be connected directly. This transforms the system into an ultra-compact all-in-one solution for monitoring complex reaction media. Intelligent LED status monitoring for weekend operation The Pt.Wireless’s key technical feature is its predictive, multi-stage energy management system, which enables a continuous operating time of up to 150 hours. To reliably prevent unforeseen system failures during critical long-term experiments, the sensor features a smart battery status warning via an integrated LED indicator. If the remaining runtime of the lithium battery falls below 70 hours, the LED signals at an early stage that safe, unattended operation over a full weekend can no longer be guaranteed. When the remaining runtime falls below a critical reserve of approximately 20 hours, the indicator changes to a slowly flashing yellow warning signal to alert laboratory staff that safe overnight operation is about to cease. Technical details Analytical & Measurement Ranges (Temperature & pH) Sensor type: PT1000 (DIN IEC 751 Class A), flexibly interchangeable Replaceable primary sensor: standard component H62.51 Temperature measurement range: –20 °C to +400 °C (depending on the H62 sensor) Temperature measurement resolution: 0.1 K Temperature measurement accuracy: ±0.2 K + tolerance of the PT1000 sensor Minimum immersion depth: 20 mm pH measurement function: Yes, via integrated BNC socket (female) pH measurement range: 0 to 14 pH pH resolution / accuracy: 0.01 pH / ±0.1 pH Wireless technology & interfaces Wireless interface: WPAN (digital radio transmission) Communication range: Up to 15 metres (depending on the building) Wired interface: USB-C (for PC connection and alternative data transfer) App connectivity: Direct pairing with the IKA app for real-time display and sensor calibration Power management & status LED Power supply: Integrated, rechargeable battery (700 mAh capacity) DC voltage: 5 V= Maximum charging current: 500 mA Operating time (with a fully charged battery): Up to 150 hours Battery charging rate: 50% charge in 60 minutes; 75% charge in 90 minutes Safety status LED: Yes, multi-stage visual remaining runtime warning (< 70 h weekend indicator / < 20 h flashing yellow signal for overnight operation) Integrated warning functions: Audible and visual via LED Dimensions & environmental data Dimensions (width x depth x height): 30 x 380 x 38 mm Net weight: 0.09 kg (extremely light at 90 grams for gentle handling) Protection class according to DIN EN 60529: IP 54 (dust- and splash-proof housing) Permissible ambient temperature: +5 to +40 degrees Celsius Permissible relative humidity: Up to 80 per cent Contents 1 x IKA Pt.Wireless wireless sensor (MPN: 0025008369) 1 x Replaceable temperature probe H62.51 1 x built-in rechargeable battery (700 mAh) 1 x USB-C connection cable 1 x Detailed operating instructions / safety guide A pH electrode is not included as standard and must be ordered separately as an accessory. Customised requirements & accessories To ensure the Pt.Wireless integrates seamlessly into your digital laboratory processes, we offer a comprehensive range of original system peripherals: pH electrodes: High-quality laboratory measuring chains with standardised BNC connectors, perfectly suited to aqueous media, viscous samples or aggressive organic matrices. Wireless receiver (USB WD): For wireless retrofitting of older RCT basic magnetic stirrers without a built-in WPAN module. Mounts & stands: Precisely fitting IKA mounting rods and cross-sockets for stable, vibration-free fixing of the sensor directly above the sample vessel. Software integration: labworldsoft (LWS) laboratory software for centralised data recording, monitoring and comprehensive documentation of all transient measurement curves. Use our technical procurement service to configure your networked measurement station.

Manufacturer's RRP: €198.00