IKA ROTAVISC me-vi HELI Complete Rotational Viscometer Set, motorised Helistand tripod, 0010013731
€2,903.60
% Manufacturer's RRP: €4,148.00 30% below manufacturer's RRP
- Rotational viscometer set with motorised Helistand stand
- For non-self-flowing samples such as creams, gels or pastes
- Viscosity measurement range 100 to 40,000,000 mPas
- TFT touchscreen display with graphing function and timer
- Includes PT-100 temperature sensor, operating temperature -100 to 300 °C
- Protection class IP 40
Product information "IKA ROTAVISC me-vi HELI Complete Rotational Viscometer Set, motorised Helistand tripod, 0010013731"
Not every sample flows evenly around the spindle of its own accord; for example, gels, ointments, creams or viscous substances tend to pool rather than flow. For precisely such cases, the ROTAVISC me-vi HELI Complete from IKA features a motorised helical stand instead of a rigid stand; this moves the spindle up and down in a controlled manner during the measurement, thereby feeding fresh sample material to the measuring head. The set combines this unique design feature with the same digital measuring head used by the other ROTAVISC variants, thereby delivering reproducible viscosity readings – which can be read directly on the instrument – even with samples that remain stationary.
Medium viscosity range with motorised helistand
The me-vi measuring system operates with a spring torque of 0.7187 mNm and covers a viscosity range from 100 to 40,000,000 mPas, with an accuracy of 1 per cent of full scale (FSR) and a repeatability of 0.2 per cent FSR. Unlike the rotastand in the lo-vi and hi-vi sets, in the me-vi HELI set the motorised Helistand tripod handles the vertical movement: the spindle dips slightly deeper into the sample and back out again at defined intervals, ensuring that even samples without their own flow movement are continuously re-measured.
TFT display, graph function and timer
Speed, torque and temperature are shown on the TFT touchscreen as setpoint and actual values, whilst a graphing function displays the viscosity curve directly on the instrument. The speed range extends from 0.01 to 200 rpm with a setting accuracy of ±0.01 rpm; the timer covers 0.017 to 6,000 minutes in timer or continuous operation. The supplied spindle set SP set-2 (SP 7 to SP 12) and the additional T-SP-SET are designed for the medium to high viscosity range.
Temperature-controlled measurement with PT 100
A PT 100.8 temperature sensor is included in the scope of delivery; it has a resolution of 0.1 Kelvin and, in conjunction with the instrument, covers an operating temperature range from minus 100 to 300 degrees Celsius. For actively temperature-controlled measurement series on non-flowing samples – such as when testing creams or gels over a defined temperature range – an external cooling/heating circulation thermostat, such as the HRC 2 lite or the CBC VISC lite, can be connected. An RS-232 interface and a micro-USB port enable connection to the Labworldsoft 6 laboratory instrument software.
Typical applications
With its motorised Helistand tripod, the ROTAVISC me-vi HELI Complete is particularly well-suited for samples that do not flow freely:
- Cosmetics and pharmaceutical testing of creams, ointments and gels
- Quality control of structurally viscous foodstuffs such as spreads or sauces
- Testing of sealants and paste-like formulations in research and development
- Formulation development for stable, non-self-levelling compounds
- In-process monitoring in the cosmetics and consumer goods industries
Brief overview within the ROTAVISC range
In addition to the me-vi-HELI model described here, IKA offers the ROTAVISC series in two further measuring range variants with a manual Rotastand tripod. The ROTAVISC lo-vi Complete measures from 1 to 6,000,000 mPas using a softer spring and is suitable for low-viscosity to medium-viscosity, self-flowing media. The ROTAVISC hi-vi II Complete, with a stiffer spring, covers the range from 800 to 320,000,000 mPas and is designed for pastes and highly viscous media that also flow freely. If the sample does not flow freely during the measurement, the motorised Helistand stand of the me-vi-HELI set described here is the more suitable design, regardless of the viscosity range.
Distinction from the CBC series with integrated temperature control
For those who regularly carry out measurements in the me-vi range at actively controlled temperatures, the ROTAVISC CBC me-vi Package offers a variant with a permanently integrated cooling/heating bath instead of an optional external thermostat. For measurements at room temperature or with occasional use of an external thermostat, the me-vi-HELI Complete Set described here remains the more compact and flexible solution, as the Helistand tripod can be used independently of the temperature control module. For particularly intensive continuous operation, IKA also offers the combination of CBC temperature control and a more robust ball bearing system in the ROTAVISC CBC SBS me-vi Package.
Technical details
| Viscosity measurement range | 100 to 40,000,000 mPas |
| Accuracy (FSR) | 1 % |
| Repeatability (FSR) | 0.2 % |
| Spring torque | 0.7187 mNm |
| Guide rail | me-vi |
| Measuring spindles | SP set-2 (SP 7 to SP 12) |
| Motor power, output | 4.8 W |
| Motor direction of rotation | clockwise, with overload protection |
| Display | TFT touchscreen with graph function |
| Speed range | 0.01 to 200 rpm, setting accuracy ±0.01 rpm |
| Torque display / measurement | Yes |
| Timer | 0.017 to 6,000 min, timer and continuous operation |
| Operating temperature | -100 to 300 °C, temperature measurement resolution 0.1 K |
| Connection for external temperature sensor | PT 100 |
| Permissible density | 9999 kg/dm³ |
| Base vessel volume | 600 ml |
| Stand | Helistand, motorised, stroke of telescopic stand 142 mm |
| Max. stroke / Ø / dynamic load (stand) | 61 mm / 16 mm / 3.2 kg |
| Interfaces | RS 232, USB (Micro-USB) |
| Protection class | IP 40 in accordance with DIN EN 60529 |
| Dimensions (W x H x D) | 351 x 629 x 372 mm |
| Weight | 7.1 kg |
| Power rating | 100 to 240 V, 50/60 Hz, 24 W |
Contents
- 1 x ROTAVISC me-vi HELI Complete (measuring head)
- 1 x SP set-2 (standard spindle set SP 7 to SP 12)
- 1 x PT 100.8 (temperature sensor)
- 1 x Helistand (motorised tripod)
- 1 x T-SP-SET
Use, installation, maintenance and disposal
The instrument is protected against solid foreign objects from 1 millimetre in size in accordance with protection class IP 40. To ensure that the Helistand can move up and down smoothly, it should be set up on a stable, vibration-free surface with sufficient headroom for the full stroke of the telescopic stand of 142 millimetres. For non-flowing, stable samples, it is advisable to clean the spindle and base vessel regularly immediately after measurement, as dried-on residues can hinder the up-and-down movement of the spindle. It is advisable to switch off the power to the device before changing the spindle or vessel. At the end of its service life, the ROTAVISC me-vi HELI Complete, as an electrical appliance, must not be disposed of with household waste but must be placed in the separate collection for waste electrical and electronic equipment. As the Helistand stand has moving mechanical parts, it is worth carrying out a quick visual check before switching it on to ensure there is sufficient clearance, so that the up and down movement does not get caught on cables or other nearby laboratory equipment.
Individual requirements & procurement service
Additional spindles and adaptors, measuring chambers, standard silicone oils for calibration, external circulating bath thermostats and the Labworldsoft 6 laboratory equipment software are available for the ROTAVISC me-vi HELI Complete if required, as are certificates for qualification (IQ/OQ) or factory calibration. Through our procurement service, LT Laborhandel will assist you in selecting from our range of viscometers.
Frequently Asked Questions
What is the motorised Helistand stand used for?
It moves the spindle up and down in a controlled manner during the measurement, ensuring that even samples which do not flow freely, such as creams or gels, are continuously re-measured.
What viscosity range is the me-vi model designed for?
For 100 to 40,000,000 mPas, with a spring torque of 0.7187 mNm.
Is the device ready for immediate use?
Yes, the measuring head, Helistand, spindle set SP set-2, T-SP-SET and PT 100.8 temperature sensor are included in the scope of delivery.
What distinguishes the me-vi-HELI model from the lo-vi and hi-vi-II models?
The lo-vi and hi-vi-II sets operate with a manual rotary stand for self-flowing media, whilst the me-vi-HELI set moves the spindle up and down by motor and is therefore suitable for non-flowing samples.
Is there a version with integrated temperature control?
Yes, the ROTAVISC CBC me-vi Package features a permanently integrated cooling and heating bath instead of an optional external thermostat.