Skip to main content Skip to search Skip to main navigation

IKA T 18 digital ULTRA-TURRAX disperser, tool-free drive unit, 500 W, 0003720000

Scope of delivery: T 18 digital drive unit. The dispersing tool shown is not included and is available separately.

ⓘ  This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.

Product information "IKA T 18 digital ULTRA-TURRAX disperser, tool-free drive unit, 500 W, 0003720000"

Anyone who frequently homogenises samples in the laboratory will be familiar with the problem: a good drive alone is not enough; ultimately, it is the right tool that determines the final fineness and throughput. The IKA T 18 digital ULTRA-TURRAX (0003720000) is designed precisely with this in mind. It is supplied as a drive unit only, with a power consumption of 500 watts, which can be freely combined with various S-18 tools for coarse, fine or single-use applications. The LED display always shows the set speed between 3,000 and 25,000 revolutions per minute, which facilitates reproducible results across multiple test runs.

Rotor-stator principle with high shear rates

During dispersion, the tool draws the sample in axially and forces it out radially through the narrow slots between the rotor and stator. This briefly generates very high shear rates, which break down solid components and mix liquids into stable emulsions or suspensions. With an output power of 300 watts and a processable volume of 0.001 to 1.5 litres (based on water), the T 18 digital covers typical laboratory batches up to a maximum viscosity of 5,000 mPas.

Stepless speed control with LED display

The speed can be adjusted continuously between 3,000 and 25,000 rpm, with a deviation of just 1 % according to IKA. Unlike purely analogue controllers, the LED display shows the set value directly. Once process parameters have been determined, they can be noted down and reproduced exactly for subsequent experiments. With a permissible duty cycle of 100 %, prolonged continuous operation is also possible without the drive having to pause in between.

The choice of tool determines the result

The T 18 digital is deliberately supplied without a dispersing tool, as the most suitable tool depends heavily on the specific sample. The standard S 18 N - 19 G tool with PTFE bearings is suitable for coarse pre-shredding and tougher media, whilst the S 18 N - 10 G offers a narrower gap geometry for finer end products. Those who frequently work with varying samples that are potentially susceptible to contamination will find disposable plastic tools to be a practical alternative, as they reduce the risk of cross-contamination between batches.

Typical applications

As a standalone drive unit, the T 18 digital is particularly suitable for laboratories that already work with a variety of tools or switch specifically between several applications:

  • Preparation of emulsions and suspensions in sample preparation
  • Homogenisation of tissue samples in biology and life sciences research
  • Mixing pigments and fillers into dispersions
  • Routine tasks in quality assurance with varying tool configurations
  • Setting up customised workstations through flexible combination with a stand and tool

Selection guide for the T-18 range

Drive unit only, complete set or just the tool? The four products compared here differ primarily in terms of what is included in the scope of delivery and, in the case of the mini-drive, in terms of motor power.

ProductTypeMotor power (input/output)Speed rangeScope of delivery
T 18 digital ULTRA-TURRAX (this product)Drive unit500 W / 300 W3,000 to 25,000 rpmDrive unit only, without tools
T 18 digital SolutionSet500 W / 300 W3,000 to 25,000 rpmDrive unit, S 18 N - 19 G tool, stand, boss head
T 18 mini digital SolutionSet, compact drive210 W / 160 W3,000 to 25,000 rpmDrive unit, tool S 18 N - 19 G, stand, boss head
S 18 N - 19 G dispersing toolSingle toolNo built-in motorPermitted up to 25,000 rpmTool only

Anyone who already owns a T-18 drive or wishes to switch between several tools as required is best served by the drive described here, which does not require a tool. The complete T 18 digital Solution Set is suitable for getting started straight away without having to order a separate tool; those looking for a more compact workstation will find the T 18 mini digital Solution to be a suitable alternative with lower motor power.

Technical details

Motor power input500 W
Motor power output300 W
Processing volume (H₂O)0.001 to 1.5 l
Max. viscosity5,000 mPas
Speed range3,000 to 25,000 rpm, continuously variable
Speed deviation1 %
Speed displayLED
Noise level without tools75 dB(A)
Support arm diameter13 mm
Support arm length160 mm
Process typeBatch
Permissible duty cycle100 %
Permissible ambient temperature range5 to 40 °C
Permissible relative humidity80 % (up to 31 °C), decreasing linearly to a maximum of 50 % (at 40 °C)
Dimensions (W x H x D)87 x 271 x 106 mm
Weight2.5 kg
Connected load220 to 240 V, 50/60 Hz, 500 W (other voltage options from 100 to 120 V available)
IP ratingIP 20 (DIN EN 60529)

Scope of delivery

  • 1 x IKA T 18 digital ULTRA-TURRAX (drive unit, without dispersing tool)

The dispersing tool and stand are not included and must be purchased separately to suit the specific application.

Differences from the neighbouring series

If you also require a brushless motor with a timer, the IKA T 18 brushless series offers the next step up: the T 18 brushless digital ULTRA-TURRAX as a drive unit without a tool, or the T 18 brushless digital Solution as a complete set. Both drive units operate with lower wear than the classic T 18 digital. An overview of all dispersers can be found in the ‘Dispersers’ category; suitable tools are listed under ‘Dispersing Tools’.

Application, set-up and maintenance

For short-term manual operation, the T 18 digital fits comfortably in the hand; for longer or reproducible processes, it can be securely mounted on a stand, such as the R 1826 plate stand. Operation is permitted at an ambient temperature of 5 to 40 °C and a relative humidity of up to 80 % at 31 °C, decreasing linearly to a maximum of 50 % at 40 °C. The drive, with degree of protection IP 20, is not designed for use in damp rooms or outdoors. After each use, the tool used should be dismantled and, depending on the material, cleaned or sterilised before the next procedure begins. At the end of its service life, as an electrical appliance, the drive must not be disposed of with household waste but must be placed in the separate collection for waste electrical and electronic equipment.

Warranty

Manufacturer’s warranty from IKA: 2 years, extended to 3 years upon registration at ika.com/register within 90 days of purchase.

Regulatory information

This device is an electrical appliance within the meaning of the German Electrical and Electronic Equipment Act (ElektroG). The WEEE registration number of the manufacturer, IKA, is DE 66784213. Information on the return of old appliances can be found on our page Environment and disposal.

Individual requirements & procurement service

In addition to the standard tools, further accessories for the T 18 digital are also available, such as stands, mounting elements or the Silentstream flow breaker to reduce air ingress during dispersion. Do you require a specific tool, a qualification document or assistance in selecting the right configuration? Through our procurement service, we can assist you with procurement and configuration.

Frequently Asked Questions

Is a dispersing tool included in the scope of delivery?
No, the T 18 digital is supplied exclusively as a drive unit. A suitable tool, such as the S 18 N - 19 G, must be purchased separately.

Which tool is suitable for coarse pre-grinding?
For coarse applications and tougher media, the S 18 N - 19 G with PTFE bearings is the standard choice; finer end products can be achieved with the S 18 N - 10 G.

How accurately can the speed be reproduced?
The LED display shows the set value within a range of 3,000 to 25,000 rpm with a deviation of around 1 %, which facilitates the exact repetition of test series.

Is a stand included in the scope of delivery?
No; for continuous operation, we recommend a separately available stand such as the R 1826 plate stand.

What is the difference between the T 18 digital and the T 18 mini digital Solution?
The T 18 mini digital Solution features a more compact, brushless drive with lower motor power and comes as a set including the tool and stand; the T 18 digital described here is the more powerful drive unit without accessories.

Skip product gallery

Matching accessories

Discount
Topseller
IKA dispersing tool S 18 N - 10 G, Ø 10 mm, L004639
IKA dispersing tool S 18 N - 10 G, Ø 10 mm, L004639
Manufacturer number: L004639

The IKA S 18 N - 10 G dispersing tool is a tool for rotor-stator dispersion in the millilitre range. Designed for use with the laboratory dispersers of the ULTRA-TURRAX T 18 series, this dispersing shaft enables sample preparation of biological, pharmaceutical and chemical media. In applications such as the disruption of tissue cells, the emulsification of cosmetic formulations or the suspension of poorly soluble active ingredients in laboratory vessels, the precise fluid-dynamic geometry of this tool supports the homogenisation of the sample. Rotor-stator kinetics and process shear dynamics The mechanical operating principle is based on the tried-and-tested rotor-stator system, in which the inner rotor moves within the fixed stator at speeds of up to 25,000 revolutions per minute. Due to the small radial gap between the rotor and stator, the sample medium is drawn axially into the dispersion head and then forced radially through the slots of the generator. The combination of high shear forces, turbulent shear fields and transient cavitation effects enables particle and droplet size reduction down to the micrometre range. The 10 G generator is characterised by an optimised tooth geometry, which enables primary fragmentation of fibrous, tough or cellular sample structures across an extended volume range. Materials and sterilisation The wetted parts are stainless steel AISI 316L (1.4404) and PTFE. According to IKA, this material composition offers high chemical resistance to acids, alkalis and organic solvents. For molecular biological and microbiological applications, the tool’s sterilisability is important: the dispersing tool is autoclavable at 121 °C and can be hot-air sterilised up to 180 °C, so that the tool can be sterilised before each use. Ergonomic design features and working area The mechanical design features a stator diameter of 10 millimetres and a shaft length of 108 millimetres, enabling operation in various reaction vessels and laboratory glassware. The working range covers a sample volume of 1 to 100 millilitres, allowing flexible sample series to be processed efficiently whilst minimising material wastage. Technical details Drive & dispersion technology Tool type: Rotor-stator dispersing tool Generator designation: 10 G Operating range (volume range H₂O): 1–100 ml Max. permissible speed: 25,000 rpm Gap width (radial gap): 0.25 mm Design & dimensions Stator diameter: 10 mm Rotor diameter: 7.5 mm Shaft length: 108 mm Minimum immersion depth: 20 mm Max. immersion depth: 85 mm Material (in contact with sample): Stainless steel (AISI 316L / 1.4404), PTFE Resistance and sterilisation Sterilisation methods: Autoclavable (121 °C), hot air (up to 180 °C) Solvent resistance: Yes Acid/alkali resistance: Yes Scope of delivery 1 x IKA S 18 N - 10 G dispersing tool Safety and cleaning instructions are enclosed Important note: A suitable drive unit from the IKA ULTRA-TURRAX T 18 series and stand accessories are not included in the standard scope of delivery and must be ordered separately. Individual requirements & accessories For the IKA S 18 N - 10 G dispersing tool to operate as intended, a drive unit from the IKA ULTRA-TURRAX T 18 series (e.g. T 18 digital) is required. To avoid abrasive wear of the internal PTFE bearings during dry running, the tool must always be immersed sufficiently deep into the sample medium (min. 20 mm) before switching on. We can source PTFE replacement seals and maintenance kits on request. Please use our procurement service to select your laboratory peripherals.

Sale price: €1,007.25 Manufacturer's RRP: €1,343.00 25% below manufacturer's RRP
Discount
Topseller
IKA S 18 N - 19 G Dispersing tool, coarse, PTFE bearings, 10 to 1,500 ml, L004640
IKA S 18 N - 19 G Dispersing tool, coarse, PTFE bearings, 10 to 1,500 ml, L004640
Manufacturer number: L004640

The IKA S 18 N - 19 G (L004640) is a tool for coarse dispersion tasks on the IKA T 18 series drives, such as the T 18 digital ULTRA-TURRAX. The stainless steel tool covers a working range of 0.01 to 1.5 litres (10 to 1,500 millilitres, based on water) and is suitable for sample preparation when grinding and mixing are required. Toothed geometry for pre-grinding The letter G in the model designation stands for ‘coarse’. Unlike fine-grinding tools, the stator of this model features a coarsely serrated geometry with a gap width of 0.25 millimetres between the rotor and stator. This makes the S 18 N - 19 G suitable for the pre-grinding of solid sample components, the mixing of pigments or fillers into coarse suspensions, and for viscous media that could clog finer tools. PTFE bearings for contact with aggressive media The rotor shaft is mounted in a PTFE bearing, as indicated by the letter ‘N’ in the model designation. PTFE is chemically almost inert, meaning the tool can, according to IKA, also be used with aggressive solvents, acids and alkalis. One important application note remains: PTFE bearings rely on the medium for lubrication and cooling; the tool must therefore not run dry, otherwise the resulting frictional heat will destroy the bearing. Hygiene and material quality The tool is made of AISI 316L stainless steel and is corrosion-resistant, durable and can be easily dismantled and sterilised for applications in the medical or microbiological fields, whether by chemical disinfection, dry heat or in an autoclave. This reduces the risk of cross-contamination between different sample batches. Typical applications According to the manufacturer, the S 18 N - 19 G is designed as a dispersing tool for T-18 drives and for volumes ranging from 10 to 1,500 millilitres. In practice, it is suitable for: Preliminary grinding of solid components in liquid samples Coarse suspensions containing pigments or fillers Viscous media that would be too viscous for finer tools Sample preparation with high requirements for chemical resistance Selection guide within the tool range In addition to the coarse version described here, there are further tools for the T-18 drives with different gap geometries or made from different materials. The S 18 N - 10 G, with a narrower gap width, is suitable for finer end products; for single-use procedures and applications where no cleaning is required between samples, the plastic tools S 18 D - 10 G - KS and S 18 D - 14 G - KS are available. Technical details Compatible drivesT 18 digital ULTRA-TURRAX and other T-18 drives (see Compatible drives)Processable volume (H₂O)0.01 to 1.5 lStator diameter19 mmRotor diameter12.7 mmGap width between stator and rotor0.25 mmMaximum permissible speed25,000 rpmMaximum circumferential speed16.6 m/sImmersion depth35 to 170 mmInstallation length204 mmMaterial in contact with the productPTFE, AISI 316L stainless steelpH range2 to 13Suitable for solventsYesSuitable for abrasive substancesYesMax. operating temperature180 °CSterilisabilityAll methodsFinal particle size of suspensions10 to 50 µmFinal particle size (emulsions)1 to 10 µmWeight0.379 kg Scope of delivery 1 x IKA S 18 N - 19 G dispersing tool A drive unit is not included; the tool is operated on a compatible T-18 drive. Compatible drives The S 18 N - 19 G is designed for use with several drives in the T-18 range: the T 18 digital ULTRA-TURRAX, as well as the T 18 digital Solution and T 18 mini digital Solution complete sets, which already include this tool. According to the manufacturer’s compatibility information, it is also compatible with the brushless drives T 18 brushless digital ULTRA-TURRAX, T 18 brushless digital Solution and the compact T 18 mini digital ULTRA-TURRAX. Use, maintenance and disposal Before first use, the tool should be securely screwed onto the drive unit and checked to ensure it is firmly in place. During operation, the tool must remain fully submerged in the medium at all times; the immersion depth ranges from 35 to 170 millimetres, depending on the container. After use, the tool can be detached from the drive unit for cleaning and, depending on requirements, chemically disinfected, treated with dry heat or autoclaved. As an accessory to an electrical appliance, the end-of-life tool must not be disposed of with household waste, but must be disposed of properly together with the associated drive unit. Individual requirements & procurement service Do you require a tool for finer emulsions, a spare part or assistance in selecting the appropriate gap geometry for your sample? Through our procurement service, we can assist you with procurement and compatibility enquiries. Frequently Asked Questions Which drives is the S 18 N - 19 G suitable for?It is suitable for the T-18 drive family, including the T 18 digital ULTRA-TURRAX and the T-18 brushless drives. What do the letters G and N in the name mean?G stands for the coarse-toothed stator geometry, and N for the PTFE bearing on the rotor shaft. Can I use the tool with solvents?Yes, the PTFE bearing is virtually chemically inert and suitable for aggressive solvents, acids and alkalis, provided the tool does not run dry. Is the tool autoclavable?Yes, according to the manufacturer, it can be sterilised using all standard methods, including autoclaving.

Sale price: €1,007.25 Manufacturer's RRP: €1,343.00 25% below manufacturer's RRP
Discount
IKA S 18/25-ET50 disposable tube, 50 ml, for S 18 D / S 25 D, 0003452500
IKA S 18/25-ET50 disposable tube, 50 ml, for S 18 D / S 25 D, 0003452500
Manufacturer number: 0003452500

Dispersion in a closed system: IKA S 18/25-ET50 disposable tube The IKA S 18/25-ET50 (MPN 0003452500) is a practical single-use tube with a volume of 50 ml. It is suitable for laboratories working with infectious, toxic or strong-smelling samples. Function: Splash protection and contamination control This tube has been specially developed for use with the disposable plastic dispersing tools from the IKA S 18 D and S 25 D series (compatible with the T 18 and T 25 drives). Easy to attach: The tube simply clips onto the shaft of the plastic tool. Sealed system: The precise fit creates a sealed chamber. The sample cannot splash out during homogenisation. Safety: It protects the user from hazardous aerosols and prevents contamination of the fume hood or the drive motor. Lower risk of cross-contamination: As both the dispersing tool (S 18 D / S 25 D) and the tube are disposed of as a whole after use, the risk of sample carry-over (cross-contamination) is reduced. Time-consuming cleaning and sterilisation are no longer necessary. Material and application The tube is made of robust polypropylene (PP). It is largely chemical-resistant and is suitable for applications in medical diagnostics, pharmaceutical research, forensic science or food analysis, where sterile or single-substance conditions are required. Technical data Model: S 18/25-ET50 Product type: Disposable sample vessel / splash guard Volume: 50 ml Material: Polypropylene (PP) Compatibility with tools: IKA S 18 D and S 25 D (disposable plastic tools) Drive compatibility: IKA T 18 (digital, brushless, mini) and T 25 (digital, easy clean, mini) Function: Enables dispersion in a sealed system Weight: approx. 0.014 kg Scope of delivery 1 x IKA S 18/25-ET50 disposable tube (50 ml) (Please note: The drive unit and disposable dispersing tools are not included and must be ordered separately!) Individual requirements & accessories To use this system, you need the appropriate IKA disposable plastic tools (e.g. S 18 D - 10 G - KS or S 25 D - 14 G - KS). We would be happy to put together the appropriate consumables sets for your T 18 or T 25 drive. Please contact our procurement service.

Sale price: €8.10 Manufacturer's RRP: €9.00 10% below manufacturer's RRP
Discount Promo
IKA S 18 D - 10 G - KS disposable dispersing tool (12 pieces), plastic, Ø 10 mm, 0003452400
IKA S 18 D - 10 G - KS disposable dispersing tool (12 pieces), plastic, Ø 10 mm, 0003452400
Manufacturer number: 0003452400

Lower risk of cross-contamination: IKA S 18 D - 10 G - KS disposable dispersing tool In sample preparation in fields such as forensics, medical diagnostics, PCR analysis or molecular biology research, sample carry-over (known as cross-contamination) can affect the results. The IKA S 18 D - 10 G - KS dispersing tool (MPN 0003452400) is intended for such scenarios. The single-use plastic tool is supplied in a pack of 12. The problem of cross-contamination and the limitations of stainless steel tools Whilst traditional stainless steel dispersing tools are durable and robust, they can have drawbacks when processing highly infectious or DNA-containing samples. To avoid carry-over of germs and DNA between two samples, a stainless steel tool must be laboriously dismantled after every single dispersing operation, cleaned manually or by machine, and then sterilised at high temperatures in an autoclave. This process ties up working time and requires the use of cleaning agents and the replacement of wear parts such as PTFE bearings. According to the manufacturer, the IKA S 18 D - 10 G - KS is designed for single use. Once the sample has been homogenised, the plastic tool is disposed of in its entirety. This reduces the risk of cross-contamination between two samples, and the cleaning effort is lower. Plastic format and rotor-stator principle The abbreviation ‘KS’ identifies the plastic version. The tool operates on the tried-and-tested rotor-stator principle and is designed for the dispersing drives of the IKA T 18 series (such as the T 18 digital, T 18 brushless digital or T 18 mini digital). With a stator diameter of 10 millimetres (indicated by the “10” in the product designation), it is designed for processing small to medium sample volumes in the range of 10 to 100 millilitres (based on water). The abbreviation “G” stands for a coarse slot geometry on the stator. This geometry is designed for the primary comminution of tough tissue, plant material or solid foodstuffs. The maximum speed is 24,000 revolutions per minute. Handling When disposable tools are used, cleaning and sterilisation between samples are no longer needed. The tool is simply fitted onto the drive, the sample is dispersed, and the tool is then ejected in a single step and disposed of properly. Areas of application Possible applications of this plastic dispersing tool are laboratories in which samples are homogenised and carry-over between samples is to be avoided. Combination with single-use tubes (splash protection) The IKA S 18 D - 10 G - KS dispersing tool can be combined with the appropriate IKA single-use tubes (such as the ET50 tube). This combination creates an enclosed system. This can reduce the risk of aerosols that may be generated during dispersion escaping into the surroundings, and thus also the contamination of laboratory equipment, pipettes and fume hoods. Technical data Model: S 18 D - 10 G - KS Product type: Disposable dispersing tool (rotor-stator) Packaging unit (PU): 12 pieces per pack Material: Plastic (KS) Stator diameter: 10 mm Rotor diameter: 6.8 mm Working range (H₂O volume): 10 to 100 ml Slot geometry: Coarse (G) Gap between rotor and stator: 0.2 mm Maximum permissible speed: 24,000 rpm Immersion depth: 15 to 85 mm Max. permissible operating temperature: 100 °C Compatible drives: IKA T 18 digital, T 18 brushless digital, T 18 mini digital Sterilisability: autoclavable Scope of delivery 1 x pack of 12 IKA S 18 D - 10 G - KS plastic dispersing tools (Note: The T 18 drive motor and any sample vessels or protective tubes that may be required are not included in the scope of delivery.) Individual requirements & accessories The combination with the IKA S 18/25-ET50 disposable tube is possible as splash protection. If you need to process sample volumes of less than 10 ml, IKA also has smaller disposable tools with a 7 mm stator diameter. Please contact our procurement service for detailed advice on your specific workflow.

Content: 12 piece(s) (€25.13 / 1 piece(s))

Sale price: €301.50 Manufacturer's RRP: €335.00 10% below manufacturer's RRP
Discount Promo
IKA S 18 D - 14 G - KS disposable dispersing tool (12 pieces), plastic, Ø 14 mm, 0003452300
IKA S 18 D - 14 G - KS disposable dispersing tool (12 pieces), plastic, Ø 14 mm, 0003452300
Manufacturer number: 0003452300

For larger volumes: the IKA S 18 D - 14 G - KS disposable dispersing tool In modern analytics, clinical diagnostics and life sciences research, the quality of sample preparation is becoming an increasingly important focus. The IKA S 18 D - 14 G - KS disposable dispersing tool (MPN 0003452300) is intended for laboratories where purity is important. As an accessory for the IKA T 18 dispersing drives (such as the T 18 digital, T 18 brushless digital or T 18 mini digital), this tool, made from plastic, offers size reduction without the risks associated with traditional reusable systems. Supplied in a practical pack of 12, it is suitable for daily high-throughput processing of medium to large sample volumes. Avoiding cross-contamination in everyday laboratory work The greatest enemy of reliable analytical results is sample carry-over, known as cross-contamination. When using conventional stainless steel dispersing tools, even after the most thorough manual cleaning, microscopic residues of tissue, proteins or nucleic acids (DNA/RNA) often remain trapped in the fine gaps between the rotor and stator or within the PTFE bearing. In highly sensitive procedures such as PCR analysis (polymerase chain reaction), forensic evidence collection or sequencing, these minimal residues can lead to false-positive results. The IKA S 18 D - 14 G - KS reduces this risk. As this is a purely single-use product, you use a fresh, unused instrument for each individual sample. After homogenisation, the entire plastic component, together with the potentially infectious or contaminated sample, is disposed of in accordance with best practice. If the tool is disposed of after use, there is no need for cleaning, rinsing or autoclaving between samples. The 14-millimetre advantage: powerful for medium volumes In direct comparison with the smaller 10-mm tools, the S 18 D - 14 G - KS model stands out due to its significantly larger stator diameter of 14 millimetres. This design expands the working range: you can homogenise volumes from 10 ml up to 500 ml (based on the viscosity of water) in a short time. The letter “G” in the product designation stands for a coarse slot geometry on the stator. This open geometry is of crucial importance when dealing with coarse-grained, tough or fibrous feed materials. Plant roots, pieces of meat, tablets or compact food samples are efficiently drawn into the shear gap by the suction forces of the 14 mm rotor, where they are cut up at speeds of up to 24,000 revolutions per minute. The result is a fine, homogeneous suspension or emulsion that is prepared for subsequent extraction or analysis. Cost-effectiveness reimagined: Total Cost of Ownership (TCO) A common objection to single-use laboratory items is the seemingly higher cost of materials. However, when a realistic full-cost analysis (Total Cost of Ownership) is carried out, the IKA S 18 D system can reduce the effort involved in tool maintenance. Consider the hidden costs of a stainless steel tool: laboratory staff spend time dismantling, scrubbing and reassembling the tools. Added to this are the running costs for distilled water, aggressive cleaning chemicals, energy consumption and the maintenance of autoclaves, as well as the inevitable wear and tear on ball bearings and seals. The single-use plastic tool S 18 D - 14 G - KS eliminates the need for all these steps. You save working time per sample, reduce downtime and can increase throughput in your laboratory. Staff can focus on value-adding analytical tasks rather than carrying out washing duties. Typical areas of use The areas of application for the 14-mm plastic tool are as diverse as they are demanding. In food testing, it is used to detect pesticide residues or pathogenic organisms in large meat or vegetable samples. In clinical pathology, it enables the safe processing of infected patient tissue. In pharmaceutical research, it is used for the size reduction of pharmaceutical formulations for active ingredient release testing. Combination with disposable tubes For work involving particularly critical media, the tool offers a further advantage: it can be combined with IKA disposable tubes (e.g. the ET50 tube). Simply attaching the tube to the tool shaft creates a largely closed system. When dispersing, the tube can reduce the escape of aerosols, vapours or splashes into the laboratory environment or the fume hood. This not only protects your valuable analytical equipment from contamination, but above all safeguards the health of your staff. Technical data Model: S 18 D - 14 G - KS Product type: Disposable dispersing tool (rotor-stator principle) Packaging unit (PU): 12 pieces per pack Material: Plastic (KS) Stator diameter: 14 mm Rotor diameter: 10.3 mm (approx.) Working range (H₂O volume): 10 to 500 ml Slot geometry: Coarse (G) for high material throughput Maximum permissible speed: 24,000 rpm Max. permissible operating temperature: 100 °C Compatible drives: IKA T 18 digital, T 18 brushless digital, T 18 mini digital Sterilisability: autoclavable according to the data sheet, designed for single use Scope of delivery 1 x pack of 12 IKA S 18 D - 14 G - KS plastic dispersing tools (Important note: The required T 18 drive motor and sample vessels are available separately and are not included in this scope of delivery.) Individual requirements & accessories Also available are the matching IKA ET50 disposable tubes, which fit onto the shaft of this tool and serve as a splash guard. Is 500 ml too large for your application? Then simply switch to the 10 mm version (S 18 D - 10 G - KS) for smaller volumes of up to 100 ml. Our procurement service will be happy to assist you in selecting the suitable tool sizes for your Standard Operating Procedures (SOPs).

Content: 12 piece(s) (€25.13 / 1 piece(s))

Sale price: €301.50 Manufacturer's RRP: €335.00 10% below manufacturer's RRP
Discount Promo
IKA R 1825 Plattenstativ für RW 20 digital Rührwerk, Höhe 560 mm
IKA R 1825 Plate Stand for RW 20 digital Overhead Stirrer, Height 560 mm, 0003160000
Manufacturer number: 0003160000

An overhead stirrer such as the IKA RW 20 digital needs its own stand to hold the drive securely above the stirring vessel. The IKA R 1825 plate stand (MPN 0003160000) is the entry-level model in the IKA stand series for this purpose, with a stable base plate on which the stirring vessel itself can also stand.With a rod height of 560 mm and a rod diameter of 16 mm, the stand has enough room to position the stirrer head above vessels of different heights, and takes up to 5 kg of load according to the manufacturer.CompatibilityOfficial accessory for the IKA RW 20 digital overhead stirrer (MPN 0003593000). For higher demands, the same series also includes the larger models R 1826 and R 1827.Technical detailsHeight560 mmBase plate (W x D)200 x 316 mmRod diameter16 mmMax. load5 kgScope of delivery1 x IKA R 1825 plate stand (MPN 0003160000).Individual requirements & procurement serviceFor mounting the overhead stirrer to the stand rod the matching IKA R 182 boss head is also available. Our procurement service also advises on the larger stand models R 1826 and R 1827 if more height or stability is required.

Sale price: €284.00 Manufacturer's RRP: €355.00 20% below manufacturer's RRP
Discount
IKA Silentstream flow breaker for dispersers, minimises air ingress, 0003754000
IKA Silentstream flow breaker for dispersers, minimises air ingress, 0003754000
Manufacturer number: 0003754000

Emulsions with less air entrapment: the IKA Silentstream flow breaker In demanding product development, cosmetic formulation, food technology and chemical synthesis, high-performance dispersion is one of the most important, yet physically demanding, methods of sample preparation. When a dispersing tool based on the rotor-stator principle operates in an open beaker or reactor at speeds of 10,000 to 25,000 revolutions per minute, it not only generates enormous shear forces to break down the particles. At the same time, a strong rotational flow is generated within the liquid. This flow leads to the formation of a deep, crater-shaped vortex. This vortex often extends right down to the stator’s suction ports. The consequence: the disperser continuously draws in ambient air into the liquid medium. IKA has developed the Silentstream accessory (MPN 0003754000). This flow baffle is a solution for reducing air ingress and improving the quality of your dispersions. The negative consequences of air entrapment in everyday laboratory work Why is air in a dispersed sample harmful? The unwanted introduction of air through vortex formation causes three major problems in everyday laboratory work: Firstly, the entrained air leads to excessive foaming. Highly foaming samples (such as protein-containing solutions or surfactant-containing shampoos) overflow from the beaker, contaminate the workstation and result in the loss of valuable sample material. Secondly, microscopic air bubbles impair the physical stability and texture of fine emulsions. A high-quality cosmetic cream or pharmaceutical ointment produced with air entrapments looks unattractive, feels dull on the skin and is prone to rapid phase separation (coalescence). Thirdly, and this is the most critical point for analytical purposes, constant contact with atmospheric oxygen at high shear rates leads to oxidation. Ingredients susceptible to oxidation, such as valuable vitamins, highly sensitive active pharmaceutical ingredients (APIs) or unsaturated fatty acids in food samples, can be damaged by this process, which can skew the subsequent analysis. The physical solution: the flow breaker principle The IKA Silentstream tackles the physical cause of this problem. The ring-shaped component is simply slid from below over the shaft of the dispersing tool (for example, the T 25 series) and positioned within the liquid medium. Thanks to its asymmetrical geometry, the Silentstream acts as a flow disruptor (flow breaker). It disrupts the uniform rotational movement of the liquid generated by the rapidly rotating rotor. The liquid is slowed down by the Silentstream and redirected into a chaotic, predominantly axial flow. The rotation of the entire fluid mass is reduced, the surface of the medium settles and the deep, air-sucking vortex is reduced. The disperser can continue to operate at high speed, but now draws in mainly liquid instead of an air-liquid mixture. Time savings and cost-effectiveness (TCO) in production Using the IKA Silentstream can also save time. If you have previously had to disperse highly foaming samples, you will be familiar with the problem of extremely long waiting times: you had to switch off the disperser after just a few seconds and wait for the voluminous foam to subside before you could continue the process. Alternatively, you had to add expensive chemical defoamers (antifoam agents), which distorted the chemical composition of your pure sample. With the Silentstream, these pauses can be shorter. You can complete the dispersion process in a single, continuous and rapid pass. This can shorten process times in your laboratory and increase daily sample throughput. Occupational health and safety and system integration A further positive side effect of the stabilised liquid surface is improved occupational health and safety. As the strong vortex and chaotic wave formation against the vessel wall are suppressed, the splashing of potentially hazardous, hot or toxic sample liquids out of the open beaker is reduced. The fume hood remains clean, and staff are protected. The Silentstream is manufactured from chemical-resistant materials. Thanks to its flow-optimised design, it can be cleaned very easily and thoroughly after use, leaving no residue, which reduces the risk of cross-contamination between different sample batches. The accessory is intended for use with IKA dispersers. Technical data Function: Flow breaker / flow stabiliser (baffle) Mode of action: Prevents vortex formation and the ingestion of air Analytical benefit: Prevents oxidation of sensitive active ingredients and foam formation Quality benefit: Produces homogeneous, air-bubble-free emulsions and suspensions Health and safety benefit: Prevents the medium from being ejected at high speeds Compatibility: Designed for mounting on the shaft of IKA dispersing tools (ideally for standard tool diameters of the T 25 series) Handling: Can be slid onto the tool shaft without the need for tools Cleaning: Easy-to-clean, chemical-resistant surfaces Scope of delivery 1 x IKA Silentstream flow breaker (Important note: The essential IKA drive motor, as well as the dispersing tool and the stand system, are available separately and are expressly not included in this scope of delivery.) Individual requirements & accessories To use this accessory, you will need a drive such as the IKA T 25 digital or T 25 easy clean control, as well as the appropriate dispersing tool (e.g. from the S 25 N series). If, despite the Silentstream, you are working with volatile solvents that must not be allowed to escape into the ambient air, we recommend switching to vacuum-tight reactor systems with the corresponding KD dispersing tools. Our procurement service will be happy to advise you on selecting the suitable tool sizes and setting up Standard Operating Procedures (SOPs) for your foam-free sample preparation.

Sale price: €21.00 Manufacturer's RRP: €28.00 25% below manufacturer's RRP