Skip to main content Skip to search Skip to main navigation

Memmert IF75plus incubator, 74 L, with TwinDISPLAY & forced air circulation

Product information "Memmert IF75plus incubator, 74 L, with TwinDISPLAY & forced air circulation"

The Memmert IF75plus incubator has an internal volume of 74 litres and external dimensions of 585 x 944 x 514 mm; its footprint is the same as that of the IF55plus. Two stainless steel wire shelves are included as part of the Scope of delivery, and up to six shelves can be fitted. The forced air circulation is generated by an electronically controlled air turbine, regulated via TwinDISPLAY using two Pt100 sensors.

Interior: narrow and tall rather than wide

The interior measures 400 x 560 x 330 mm (W x H x D) and is reinforced by deep-drawn ribbing; the 4-sided all-round heating is integrated and protected. With an internal height of 560 mm, the IF75plus is taller than the next model up, the IF110plus, which has an internal height of 480 mm, but is narrower (400 mm instead of 560 mm). The IF75plus accommodates up to six racks, one more than the larger-capacity IF110plus, which holds five. The permissible total load is 120 kg, with a maximum of 20 kg per rack; the net weight is approximately 66 kg.

ControlCOCKPIT and process protection

Firstly, regarding safety: AutoSAFETY automatically monitors the temperature at a freely selectable margin from the setpoint and signals deviations visually and acoustically; independently of this, the mechanical temperature limiter of protection class 1 in accordance with DIN 12880 engages at around 20 °C above the maximum cabinet temperature. Optionally, a Class 3.1 temperature selector monitor or an adjustable temperature limiter of Class 2 can be set on the display; a self-diagnostic system assists with fault finding. The temperature is measured by two DIN Class A Pt100 sensors that monitor each other; the setting accuracy is 0.1 °C, and the setting temperature range extends from +20 to +80 °C. HeatBALANCE distributes the heating power between the upper and lower heating groups by between -50 and +50 per cent; SetpointWAIT delays the start of the process until the setpoint temperature has been reached; and AtmoCONTROL manages programmes via Ethernet or USB. For internal sterilisation, there is a pre-set programme at 160 °C for 4 hours; this does not apply to any load placed inside the chamber. Operation is approved for ambient temperatures of +5 °C to +40 °C, a maximum relative humidity of 80 per cent (non-condensing) and installation altitudes of up to 2,000 m above sea level.

Guide to selecting the right size

For those incubating fewer batches at a time, the IF55plus (53 l) is a smaller benchtop unit. If more internal volume is required and five racks are sufficient instead of six, the IF110plus, with 108 litres, offers greater depth and width; see the size table below.

Typical applications

As an incubator with forced air circulation, the IF75plus is used for incubating and temperature-controlling samples and is employed in research, medicine, pharmacy, food analysis and food chemistry.

  • Incubating and temperature-controlling several small batches in parallel
  • Incubation processes in medicine and pharmacy
  • Incubation and temperature control of samples in food analysis and food chemistry

Technical details

Temperature setting range+20 to +80 °C
Operating temperature rangeat least 10 °C above room temperature up to +80 °C
Temperature setting accuracy0.1 °C
Temperature sensor2x Pt100, DIN Class A, 4-wire measurement, redundant
Internal volume74 l
Internal dimensions (W x H x D)400 x 560 x 330 mm
External dimensions of housing (W x H x D)585 x 944 x 514 mm
Net weightapprox. 66 kg
Power supply 230 V50/60 Hz, approx. 1,250 W
Connection 115 V50/60 Hz, approx. 900 W
Maximum number of trays6
Slots in the scope of delivery2
Max. load on unit120 kg
Max. load per drawer20 kg
ControlControlCOCKPIT TwinDISPLAY, PID microprocessor controller, 2x TFT colour graphic displays
Additional functionsHeatBALANCE, SetpointWAIT, AutoSAFETY, visual and audible alarm
Permissible ambient temperature+5 °C to +40 °C
Permissible relative humiditymax. 80% rel., non-condensing
Maximum installation height2,000 m
CertificationsCE, VDE GS, UL, EAC

Other sizes in the series

The IF-plus series comprises eight sizes ranging from 32 to 749 litres with TwinDISPLAY, listed below by internal volume:

ModelInternal volumeSet temperatureDisplay
IF30plus32 l+20 to +80 °CTwinDISPLAY
IF55plus53 l+20 to +80 °CTwinDISPLAY
IF75plus (this page)74 l+20 to +80 °CTwinDISPLAY
IF110plus108 l+20 to +80 °CTwinDISPLAY
IF160plus161 l+20 to +80 °CTwinDISPLAY
IF260plus256 l+20 to +80 °CTwinDISPLAY
IF450plus449 l+20 to +80 °CTwinDISPLAY
IF750plus749 l+20 to +80 °CTwinDISPLAY

We stock the same size model with a single temperature sensor and SingleDISPLAY instead of the two monitoring Pt100 sensors as the IF75.

Scope of delivery

  • 1x Memmert IF75plus incubator
  • Factory calibration certificate (calibrated at +37 °C)
  • Fully insulated stainless steel door with 2-point locking (compression door seal)
  • Inner glass door
  • 2x stainless steel wire mesh shelves, electropolished

Regulatory information

This appliance is an electrical appliance within the meaning of the German Electrical and Electronic Equipment Act (ElektroG). The WEEE registration number of the manufacturer, Memmert GmbH + Co. KG, is DE 66812464. Information on the return of end-of-life appliances can be found on our Environment and Disposal page.

Individual requirements and procurement service

For the IF75plus, the following items, amongst others, can be ordered ex-works: interior lighting, temperature throttling, door-open detection and a lockable door. Available accessories include an additional perforated stainless steel panel, a slide-in drip tray, a wall bracket, a stacking kit and a levelling or mobile base frame. For calibration and qualification, we arrange DAkkS calibrations as well as IQ/OQ/PQ documentation. We are happy to advise you personally on any individual requirements.

Volume: 74 l