Skip to main content Skip to search Skip to main navigation

IKA RV 10 digital pro V-C double Complete, Two Rotary Evaporators with a Shared Heating Bath, Vacuum Pump and Recirculating Cooler, 0010012327

Product information "IKA RV 10 digital pro V-C double Complete, Two Rotary Evaporators with a Shared Heating Bath, Vacuum Pump and Recirculating Cooler, 0010012327"

The RV 10 digital pro V-C double Complete is the version with a coated glass set within the double sets: two complete rotary evaporator drive units share one HB digital heating bath, one VACSTAR digital vacuum pump and one RC 2 GREEN basic recirculating cooler. According to the manufacturer, a single vacuum source is sufficient to supply both rotary evaporators. Each drive unit has its own VC 10 pro vacuum controller, so that both evaporators can be controlled independently of one another. Compared with two separate single sets, this eliminates the need to purchase a pump, heating bath and cooler twice.

Two drive units with coated glass

Both drive units feature a motorised lift with a 140-millimetre stroke and a safety-stop function, which automatically raises the evaporator flask out of the heating bath in the event of a power cut. Individually adjustable safety temperature circuits, dry-run protection and adjustable end-of-stroke detection protect both evaporators independently against glass breakage. The coated glass set makes efficient use of the cooling surface via a specially developed glass guide; the speed per drive unit ranges from 5 to 280 revolutions per minute.

RC 2 GREEN basic recirculating chiller

The shared RC 2 GREEN basic recirculating chiller cools down to minus 30 degrees Celsius with a cooling capacity of 800 watts; the compressor operates with demand-based and speed-controlled operation. The natural refrigerant R290 is also used here. The VACSTAR digital vacuum pump achieves a minimum vacuum of 2 millibars and supplies both evaporators via the two separate VC 10 vacuum controllers.

Typical applications

  • Double evaporation capacity at a single workstation with coated glass for aggressive or valuable samples
  • Parallel runs in research and development that are to be distilled simultaneously
  • Training laboratories where two workstations need to be served by a single vacuum source
  • Laboratories with increased cooling requirements, where the higher cooling capacity of the RC 2 GREEN basic is essential

Selection guide: an overview of the Complete and Starter sets

Within the double sets, this variant differs from the version with uncoated glass only in terms of the glass set coating; the peripheral concept, featuring a shared heating bath, shared pump and shared cooler, is identical. Compared with the single Complete variant of the digital range, this version features two drive units instead of one. Across all series, the key factors are the heating bath temperature, the speed range and the number of drive units per peripheral.

ModelSeriesGlass setPeripherals in the setKey feature
RV 3 V Starter SolutionRV 3uncoatedVACSTAR lite, HB ecoEntry-level model in the RV 3 series
RV 3 pro V-C CompleteRV 3coatedVACSTAR digital, VC 10 lite, HB eco, RC 2 liteHeating bath up to 99 °C, speed up to 300 rpm
RV 8 V Starter SolutionRV 8uncoatedVACSTAR lite, HB digitalEntry-level model in the RV 8 series
RV 8 pro V-C CompleteRV 8coatedVACSTAR digital, VC 10 lite, HB digital, RC 2 liteHeating bath up to 180 °C, speed up to 300 rpm
RV 10 auto V Starter SolutionRV 10 autouncoatedVACSTAR lite, RC 2 liteTFT colour display, integrated vacuum controller
RV 10 auto pro V-C CompleteRV 10 autocoatedVACSTAR digital, RC 2 liteTFT colour display, integrated vacuum controller
RV 10 digital pro V-C CompleteRV 10 digitalcoatedVACSTAR digital, VC 10 lite, HB digital, RC 2 liteRS-232 interface, motorised lift, one drive unit
RV 10 digital pro V double CompleteRV 10 digitaluncoated1x VACSTAR digital, 2x VC 10 pro, 1x HB digital, 1x RC 2 GREEN basictwo drive units on a single peripheral
RV 10 digital pro V-C double Complete (this product)RV 10 digitalcoated1x VACSTAR digital, 2x VC 10 pro, 1x HB digital, 1x RC 2 GREEN basicTwo drive units on a single peripheral

Technical details

Cooler designvertical, coated
Motor principleDirect current
Speed range (per drive unit)5 to 280 rpm
Direction of rotation reversibleYes
Liftmotorised, stroke 140 mm (per drive unit)
Heating temperature rangeRoom temperature to 180 °C
heating power1300 W
Max. heating bath capacity4 l
Integrated vacuum regulatorYes, measurement accuracy ±2 mbar, control and measurement range 1050 to 1 mbar
TimerYes
VACSTAR digital vacuum pumpMinimum vacuum 2 mbar, shared between both drive units
RC 2 GREEN basic circulation chiller800 W cooling capacity, down to -30 °C, demand- and speed-controlled compressor, R290 refrigerant
Permissible ambient temperature / humidity5 to 40 °C / 80 %
Protection classIP 20 in accordance with DIN EN 60529
InterfaceRS-232
Dimensions (W x H x D, per drive unit)500 x 430 x 440 mm
Weight (per drive unit)21.5 kg
Connected load220 to 240 V, 50/60 Hz, 1400 W Power consumption per drive unit (other voltage options: 115 V / 100 to 120 V / 100 to 115 V)

Scope of delivery

  • RV 10 digital V-C drive unit, 2 pieces, ID no. of this complete product 0010012327
  • VC 10 pro vacuum controller, 2 units, ID no. 0020112031
  • VACSTAR digital vacuum pump, shared between both drive units, ID no. 0020016236
  • VC 10.400 support rod, 2 pieces, ID No. on request
  • Circulating cooler RC 2 GREEN basic, shared between both drive units, ID no. 0025004186
  • Hose set RV 10.5005, 2 pieces, ID No. 0020000552
  • Y-hose connector 8 mm, 2 pieces, ID No. on request
  • Safety accessories VSE 1, ID no. on request
  • Non-return valve VC 10.300, 2 pieces, ID no. on request
  • HB digital heating bath, shared between both drive units, ID No. 0020016334
  • Coated vertical glass cooler set with 1-litre collection and evaporator flasks, 2 pieces, ID No. on request

Warranty and procurement service

The IKA manufacturer’s warranty applies to both drive units and the heating bath: 2 years, extended to 5 years upon registration at ika.com/register within 90 days of purchase. For the VACSTAR digital vacuum pump, both VC 10 pro vacuum controllers and the RC 2 GREEN basic recirculating cooler, the 2+1 warranty level applies; upon registration, this means 3 years instead of 5. For a third rotary evaporator connected to the same peripheral equipment or additional glassware sets, LT Laborhandel’s procurement service will put together the appropriate configuration.