Memmert Incubator IF260mplus, 256 l, +20 to +80 °C, TwinDISPLAY
€5,016.00
Available, delivery time: 2-3 weeks
- Class I medical device under Regulation (EU) 2017/745
- Intended purpose: tempering of irrigation and infusion solutions and contrast media
- 256 l internal volume, TwinDISPLAY with 2 TFT colour graphic displays
- HeatBALANCE: adjustable heating power distribution -50 % to +50 %
- 2x redundant Pt100 sensors with function takeover in the event of a fault
- AutoSAFETY monitoring with visual and audible alarm
- Factory calibration certificate included (calibration at +37 °C)
Product information "Memmert Incubator IF260mplus, 256 l, +20 to +80 °C, TwinDISPLAY"
With 256 litres and up to nine shelves, the Memmert Incubator Im IF260mplus is the largest model in the IF-mplus series without castors. Its intended purpose as a Class I medical device under Regulation (EU) 2017/745 covers the tempering of irrigation and infusion solutions and contrast media. Two stainless steel grid shelves are included as standard.
Redundant temperature measurement
If one of the two Pt100 sensors of DIN class A fails, the second one automatically takes over its function, and both measure using 4-wire technology. The setting temperature range is +20 to +80 °C, and the setting accuracy is 0.1 °C. Two TFT colour graphic displays of the ControlCOCKPIT TwinDISPLAY show the values, and HeatBALANCE adjusts the heating power distribution between the upper and lower heating group in the range of -50 to +50 percent.
Programs and logging
Programs can be created and transferred with AtmoCONTROL via Ethernet or USB, and the program sequence remains stored in the event of a power failure. SetpointWAIT only starts the process time once the set temperature has been reached, and three values can be freely calibrated.
Limit values and sterilisation
A mechanical temperature limiter of protection class 1 to DIN 12880 switches the heating off at approx. 20 °C above the maximum cabinet temperature. In addition, an adjustable temperature monitor of protection class 3.1 or an adjustable temperature limiter of protection class 2 can be set on the display. A self-diagnosis system assists with fault finding. A permanently installed sterilisation program (4 h at 160 °C) is used for sterilising the interior; it is not intended for sterilising load items.
AutoSAFETY alarm function
AutoSAFETY monitors exceedances and shortfalls of the set value within a freely adjustable range. In the event of a deviation, the device signals visually and audibly, and if the value is exceeded, the heating switches off.
Dimensions, weight and connection
Internally, the IF260mplus measures 640 x 800 x 500 mm and externally 824 x 1,183 x 684 mm, with a net weight of approx. 110 kg. A fully insulated stainless steel door with 2-point locking and an inner glass door close the chamber, and the stainless steel interior is deep-drawn, ribbed and heated all round. The device is operated at 230 V with approx. 1,700 W or at 115 V with approx. 900 W, and a total load of 300 kg is permitted at 20 kg per shelf.
Technical differences from IF260m and IF260plus
The IF260m is controlled via a SingleDISPLAY with only one Pt100 sensor and without HeatBALANCE, and its intended purpose is different: heating and keeping warm fango, silicate and APS packs in physiotherapy. The laboratory incubator IF260plus is also equipped with TwinDISPLAY, but has no medical intended purpose.
Smaller and larger alternative
The smaller IF160mplus offers 161 litres with eight shelves. The larger IF450mplus offers 449 litres, stands mobile on castors and allows 30 instead of 20 kg per shelf.
Typical applications
As a Class I medical device, the IF260mplus is intended for:
- Tempering of irrigation solutions
- Tempering of infusion solutions
- Tempering of contrast media
Technical details
| Setting temperature range | +20 to +80 °C |
| Working temperature range | min. 10 °C above room temperature to +80 °C |
| Temperature setting accuracy | 0.1 °C |
| Temperature sensor | 2x Pt100, DIN class A, 4-wire measurement, redundant |
| Internal volume | 256 l |
| Internal dimensions (W x H x D) | 640 x 800 x 500 mm |
| External dimensions of housing (W x H x D) | 824 x 1,183 x 684 mm |
| Net weight | approx. 110 kg |
| Connection | 230 V, 50/60 Hz, approx. 1,700 W; 115 V, 50/60 Hz, approx. 900 W |
| Shelves in scope of delivery | 2 |
| Shelves, maximum | 9 |
| Max. load, unit | 300 kg |
| Max. load per shelf | 20 kg |
| Control | ControlCOCKPIT TwinDISPLAY, PID microprocessor controller, 2x TFT colour graphic display |
| Additional functions | HeatBALANCE, AutoSAFETY, SetpointWAIT, programming via AtmoCONTROL (Ethernet/USB) |
| Medical device classification | Class I under Regulation (EU) 2017/745 |
| Intended purpose | Tempering of irrigation and infusion solutions and contrast media |
| Permissible ambient temperature | +5 °C to +40 °C |
| Permissible humidity | max. 80 % rel., non-condensing |
| Markings | CE, VDE, cULus |
Other sizes in the series
The mplus series ranges from 32 to 749 litres across eight chamber sizes, all with TwinDISPLAY and the setting temperature range +20 to +80 °C. At 256 litres, the IF260mplus is in the upper range.
| Model | Internal volume | Setting temperature | Display |
|---|---|---|---|
| IF30mplus | 32 l | +20 to +80 °C | TwinDISPLAY |
| IF55mplus | 53 l | +20 to +80 °C | TwinDISPLAY |
| IF75mplus | 74 l | +20 to +80 °C | TwinDISPLAY |
| IF110mplus | 108 l | +20 to +80 °C | TwinDISPLAY |
| IF160mplus | 161 l | +20 to +80 °C | TwinDISPLAY |
| IF260mplus (this page) | 256 l | +20 to +80 °C | TwinDISPLAY |
| IF450mplus | 449 l | +20 to +80 °C | TwinDISPLAY |
| IF750mplus | 749 l | +20 to +80 °C | TwinDISPLAY |
Scope of delivery
- 1x Memmert Incubator Im IF260mplus
- Factory calibration certificate at +37 °C
- Fully insulated stainless steel door with 2-point locking (compression door seal)
- Inner glass door
- 2x stainless steel grid shelf, electropolished
Regulatory information
The device is electrical equipment within the meaning of the German Electrical and Electronic Equipment Act (ElektroG). The WEEE registration number of the manufacturer Memmert GmbH + Co. KG is DE 66812464. Information on the return of old equipment can be found on our page Environment and disposal. The IF260mplus is also classified as a Class I medical device under Regulation (EU) 2017/745; its intended purpose is the tempering of irrigation and infusion solutions and contrast media.
Individual requirements and procurement service
The 115 V voltage variant and temperature throttling are available as factory options for the IF260mplus. For accessories, we source reinforced grid shelves, perforated trays, insert and base drip trays, a built-in frame, a USB-Ethernet adapter and a levelable base frame. For DAkkS calibration, IQ/OQ/PQ documentation and qualification as well as maintenance contracts, we put you in touch with the right contact. Contact us for individual advice.
| Volume: | 256 l |
|---|